← All decks

ENT

Active Middle Ear Implants

Built from Haynes-Glasscock-Shambaugh Surgery of the Ear, Seventh Edition

What’s inside

11 sections · 105 slides

  1. 01

    Overview

    • Scope of this presentation

    1 slide

  2. 02

    The unmet need in hearing rehabilitation

    • Burden of hearing loss and hearing aid uptake
    • Medical contraindications to conventional aids
    • Public health consequences of untreated hearing loss

    3 slides

  3. 03

    Limitations of conventional amplification

    • Five limitations of conventional hearing aids
    • Insufficient gain in moderately severe and severe loss
    • Distortion and the occlusive seal
    • Behind-the-ear aid with occlusive earmould
    • Open-fit aids and transduction inefficiency
    • How active middle ear implants address these limits

    6 slides

  4. 04

    Basic design features

    • Signal pathway of an active middle ear implant
    • Electromagnetic transducers
    • Piezoelectric transducers
    • Coupling sites for the transducer
    • Semi-implantable and fully implantable configurations
    • Partially implanted devices
    • Fully implantable devices
    • Cochlear tonotopy and the implant target
    • Frequency map of the cochlea in the intact ear

    9 slides

  5. 05

    Challenges and opportunities

    • Professional endorsement and current status
    • Cost and reimbursement barriers
    • Device longevity compared with cochlear implants
    • Cost-effectiveness evidence
    • Industry instability and regulatory burden
    • Quality of the evidence base

    6 slides

  6. 06

    The three FDA-approved devices

    • Reading the device comparison
    • Distinctions between the FDA-approved active middle ear implants
    • FDA-approved indication for each device

    3 slides

  7. 07

    MED-EL Vibrant Soundbridge

    • Development history of the Vibrant Soundbridge
    • Components of the Vibrant Soundbridge
    • Working principle of the vibrating ossicular prosthesis
    • Indications for the Vibrant Soundbridge
    • Degrees of hearing loss plotted on the audiogram
    • Range of pathology treated with the Soundbridge
    • Mixed hearing loss on pure tone audiometry
    • Surgical technique for Soundbridge implantation
    • Crimping force on the incus long process
    • Postoperative threshold shift with the Soundbridge
    • Functional gain compared with hearing aids
    • Speech discrimination with the Soundbridge
    • Systematic review in conductive and mixed loss
    • Patient-reported outcomes with the Soundbridge
    • Quality of life in external otitis and bilateral implantation
    • Explantation and revision rates
    • Revision by coupling site
    • Other adverse events and comparative safety
    • MRI compatibility of the Vibrant Soundbridge

    19 slides

  8. 08

    Ototronix MAXUM

    • From SOUNDTEC to MAXUM
    • Components of the MAXUM system
    • Ear canal coil and incudostapedial joint magnet in position
    • Audiometric criteria for the MAXUM system
    • Speech perception gap as a selection tool
    • Overlap with cochlear implant candidacy
    • Preoperative ear canal assessment
    • Surgical technique for MAXUM implantation
    • Magnet positioning and functional gain
    • Avoiding contact of the magnet
    • Threshold change after implantation
    • Significant threshold shifts after surgery
    • Functional gain over best-fit hearing aids
    • Speech discrimination results
    • MAXUM in potential cochlear implant candidates
    • Patient-reported outcomes and complications
    • Complications of MAXUM and SOUNDTEC implantation
    • MRI compatibility of the MAXUM implant

    18 slides

  9. 09

    Envoy Esteem

    • Position of the Esteem among implants
    • Signal path through the Esteem
    • Implanted components of the Esteem
    • Ossicular disarticulation and irreversibility
    • Indications and preoperative imaging for the Esteem
    • Space requirements on preoperative CT
    • Surgical approach for the Esteem
    • Transducer placement and feedback control
    • Threshold and audiometric outcomes with the Esteem
    • Speech testing results with the Esteem
    • Patient-reported outcomes with the Esteem
    • Device malfunction and explantation
    • Infection, exposure and surgeon experience
    • Facial nerve injury after Esteem surgery
    • Proposed mechanisms of delayed facial paresis
    • Revision surgery for the Esteem
    • Other adverse events and MRI status

    17 slides

  10. 10

    Summary

    • Key points on active middle ear implants
    • Outstanding barriers and future direction

    2 slides

  11. 11

    References

    • References
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • References (continued)
    • Haynes-Glasscock-Shambaugh Surgery of the Ear, Seventh Edition
    • Join our WhatsApp groups

    11 slides