Ultrasound Physics for the Clinician

Built from Obstetric Imaging

What’s inside

7 sections · 64 slides

  1. 01

    Overview

    • Scope of this topic
    • Components of an imaging system
    • The six components in an ultrasound scanner

    3 slides

  2. 02

    The ultrasound pulse

    The stimulus: what the probe actually sends into the body

    • Nature of the ultrasound pulse
    • Compression and rarefaction
    • Longitudinal and transverse waves
    • Amplitude and frequency of the pulse
    • 20 Hz – 20 kHz
    • Why the prefix ultra-
    • Volume occupied by the ultrasound pulse
    • Propagation of the ultrasound pulse from the transducer
    • Reading the pulse propagation diagram
    • Axial, lateral, and elevational dimensions
    • Beam geometry and the focus

    11 slides

  3. 03

    The body as an acoustic object

    What the pulse meets once it is inside the patient

    • Acoustic impedance
    • Sound speed in soft tissue
    • 1750 m/s

    3 slides

  4. 04

    The echo

    The response: how tissue answers the pulse, and what dims that answer

    • Origin of the echo
    • Factors that set echo amplitude
    • Reflection from large interfaces
    • Coupling gel and the acoustic window
    • Scattering from tissue microstructure
    • Reflection compared with scattering
    • Formation of speckle
    • Speckle texture on a clinical scan
    • Echogenicity and its descriptive terms
    • Darker and brighter regions side by side
    • Attenuation
    • Causes of attenuation
    • Decibels and typical attenuation values
    • Time-gain compensation
    • Detector sensitivity and echo amplitude

    15 slides

  5. 05

    Making the image

    Transducer, pulse-echo listening, and building the B-mode picture

    • The ultrasound transducer
    • Piezoelectric elements and the array
    • Ultrasound transducer contact face
    • The aperture and pulse-echo listening
    • Converting echo arrival time into depth
    • Formation of a B-mode image
    • Echo signal along a single scan line
    • Grey-scale B-mode image built from many scan lines
    • Building the B-mode image line by line
    • Array type and image geometry
    • Linear, curvilinear, and phased arrays
    • Electronic delays in a phased array

    12 slides

  6. 06

    Image quality and its trade-offs

    Spatial, temporal, and contrast resolution — and what each one costs

    • Three primary determinants of image quality
    • Spatial resolution
    • Frequency and spatial resolution
    • Resolution versus penetration
    • Choosing a transducer for the depth of interest
    • Practical consequence of the frequency trade-off
    • Temporal resolution
    • Contrast resolution
    • Cost of noise averaging

    9 slides

  7. 07

    Safety and the ALARA principle

    What the referring physician needs to know about acoustic energy

    • Acoustic energy deposition in tissue
    • The ALARA principle
    • “
    • From pulse to picture
    • Key points
    • Vocabulary to carry away
    • References
    • References (continued)
    • References (continued)
    • Suggested readings
    • Obstetric Imaging: Fetal Diagnosis and Care, 2nd Edition

    11 slides